| New Auto Coordination & Evaluation Module! |
This new module is designed to instantly
identify coordination and protection issues by evaluating each
equipment for adherence to basic coordination and protection rules
established by the National Electrical Code (NEC) and recommended
industry standard practices.
Violations
can then be resolved systematically at each location/zone either
manually or automatically by creating TCC drawings of the affected area
with a single click. The auto coordination feature will attempt to make
the minimum amount of changes to the existing coordination and resolve
the violations by changing protective equipment settings or frame
sizes. New settings can be reviewed or reverted back to the original
settings.
|
|
|
|
|
Automatically
sizes Cables, Transformers, Buses, and Protective Devices to achieve
proper size and ratings that meets criteria limits set by the Equipment
Evaluation study. This software is best suited for new system
designs or to resolve undersized and/or overdutied equipment for
existing systems. Includes user-defined Design libraries to specify
equipment that is often purchased.
- Helps
you design safer and more cost effective power systems for low, medium,
and high voltage systems.
- Works
seamlessly with the Equipment Evaluation module.
- Saves
you time by automatically entering equipment data for all components
based on preset libraries with one click.
- Increases
flexibility by allowing user defined libraries for cables,
transformers, buses, and protective devices.
- Increases
flexibility by auto designing based on equipment type or equipment
manufacturer.
- Saves
you time by generating a report that compares "As Found" information
with "Auto Design" results.
- Communicate
designs more effectively with professional reports and annotated
one-line diagrams.
- Allows
for consistent designs throughout the system.
- Complies
with NEC and other requirements.
- Note: Auto Design requires Equipment Evaluation module.
|
|
|
|
| 2018 SKM Training Schedule |
|
We trained over 1,000
engineers in our 2017 hosted and onsite classes! See what they
say in our Spotlight section.
We are proud to release our
upcoming 2018 training schedule. From software training,
protection, arc flash analysis, grounding, motor starting, and
harmonics, we have something for everyone to enjoy. 2018 Arc
Flash classes will also cover changes in NFPA 70E 2018. Join us
and
see why thousands of
power engineers have praised our training to be the best in the
industry. |
|
Training more than 5 engineers? Email training@skm.com for a personalized
On-Site Training quote.
|
|
|
| |
New Training Location in Los
Angeles!
|
We are pleased to announce a new location
for our Los Angeles classes! 2018 classes will be held at the
Torrance Marriott South Bay hotel.
- Torrance Marriott Redondo Beach
Hotel is only minutes away from miles of pristine California
Beaches. Convenient to Los Angeles International (LAX) and Long
Beach (LGB) airports, the Torrance Marriott South Bay hotel is where
style meets coastal comfort.
- Relax in spacious guest rooms with
luxury bedding, 49" Televisions and wireless internet.
- Elevate your spirit in the Village
Square, a lush green outdoor venue with an indoor/outdoor pool.
- 21 Square bar+kitchen bridges the
gap between the city and the beach with a locally inspired style that
celebrates the sea.
The first Los Angeles class will be held January 29 - Feb 2, 2018 and
will feature new changes to NFPA 70E 2018 and NESC C2-2017.
NESC 2017 features:
- Updated Arc Flash NESC method to the current 2017 standard
- Updated Minimum Approach Distance (MAD) tables
- Added NESC labels
- Utilize phase-to-ground arc faults
- User-definable factor for three-phase applications
- Voltage range up to 800kV
- Duration of arc automatically defined by the protective device TCC or by user input
- Selection of Supply and Communications work
- Automated selection of Separation
Distance, Minimum Approach Distance (MAD), Gap, and Rubber Insulating
Equipment Class per current NESC standard
- Various selection of equipment type
- Includes provision for altitude correction factors
- Report worst-case incident energy among multiple scenarios
- Various selection of stock Arc Flash labels styles
- Fully-customizable Arc Flash labels
- Multiple label printing
- Export Arc Flash results to a spreadsheet
- User-definable Personal Protective Equipment (PPE) table
- Color-coded Arc Flash results viewed in oneline drawings
- Find Bus and Protective Device in onelines and TCCs from the Arc Flash table
- Arc Flash datablocks for Oneline, TCC, and reports
- Enter and store user notes for individual locations
- Report overdutied equipment
Let our engineers show you the best way to get the most out of your software investment! Our
courses help you achieve your goals, whether you want to improve your
skills, resume training, or learn how to use Power*Tools for the first
time. SKM training provides you with the correct mixture of
lecture,
demonstration, and hands-on exercises to maximize your learning
experience. Join us and boost your productivity by learning how to use
your Power*Tools software more effectively!
Classes fill
up quickly, so sign up today!
|
|
|
| |
SKM Help Desk and Chat
|
|
Questions? Check out
our Knowledge base! Need more help? Submit a ticket
through our Help
Desk. With the Help Desk:
- Submit tickets
- Easily access and manage your
tickets.
- Attach documents
- View history of all your tickets,
along with responses from our technical staff.
|
|
|
 |
|
....
|
Have a
question? Chat with us!
Live
chat is now available 7am - 4pm Monday - Friday! We added chat
services so that you can get immediate access to our Support and Sales
staff. SKM is committed to providing all our customers the best
in customer service. Go to
www.skm.com and look for the green chat button. Ask us anything!
|
|
| |
My SKM Customer Portal
|
The My SKM customer portal is now
live! Go to www.skm.com
to login today! You'll be able to:
- Order new products
- Add modules or upgrade an existing license
- Calculate maintenance fees
- Pay invoices online
- View license Information
- Manage company information
- Retrieve pending quotes
- Register for training
- Manage newsletter subscriptions
and more!
If you are the main registered user, an account
has been created for you. Simply click on "Forgot your password?" for
it to be emailed to you. If you have trouble logging in or would like
to update your account records, email us at sales@skm.com.
|
.
|
|
|
| Solutions For a Growing Industry |
| As
the Power Systems Industry grows and new technologies emerge, more
advanced studies will be required. Our state-of-the-art software will
be there every step of the way. Whether it be Reliability studies or
Harmonic Analysis, SKM will have you covered. Contact us for more
information or if you would like a free no-risk demo. |
| Personal Computing |
As
our software progresses and our users evolve, there’s an increasing
demand to create a customized experience. Power*Tools is the most
flexible and customizable software on the market today. Create custom
Datablocks, reports, multi-language arc flash labels, one-line
templates, and more — quickly and painlessly.
|
| Spotlight |
Here
are some comments from our previous courses:
“[Instructor] is probably the best communicator I have taken in my 35
years of work. ”
“Extremely well designed class. Good instructor and he was able to pace
the class and present the material in an effective manner.”
“The handbook was especially helpful. Instructor clarified some of my
misunderstandings.”
“The step-by-step instruction throughout reinforced the processes. That
made it easy to remember what I was going to do after awhile. I wish I
had taken it 10 years ago!!!”
“It was one of the best trainings I’ve been to. You kept me engaged
with very little unnecessary down time and kept the class casual enough
where everyone felt comfortable. I appreciate the fact that time seemed
to go by very quickly and at the same time I learned a lot more about
the software than I thought was possible. The hotel amenities were great as well.” |
| Earn Professional Hours by taking SKM
Courses! |
| All
our courses are certified by the IEEE organization to provide you
with Continuing Education Credits or Professional Development Hours.
Don’t let your Professional license expire. Sign up today! |
| Contact Us to Schedule your Next On-Site
Training! |
| Too
busy to fly? Have more than 5 engineers to train? No problem, we’ll
come to you! Contact us to receive your personalized quote for on-site
training. |
| |
|
| |
| Client Spotlight |
| If
you are involved with an exciting project or you would like your
company to be featured in a future newsletter, send us an email at
sales@skm.com |
Thank you for Your Referrals
|
SKM,
like other companies, relies heavily on word-of-mouth advertising. If
you are satisfied with our software products and support services, tell
a colleague. If you are unsatisfied with any aspect of our products or
service, please tell us so we can address the situation. Your customer
referrals are greatly appreciated, and your complete satisfaction is
our priority.
|
| |
SKM Systems Analysis, Inc.
1 Pearl Street
Redondo Beach, CA 90277
1-800-500-4SKM
1-800-222-4SKM (fax)
sales@skm.com
support@skm.com
www.skm.com |
| |
|
|